Features:
  • Fully computer controlled (Mac and PC based)
  • E9-Screen software for automatic selftest and calibration
  • Automatic recognition of the amplifier type by the acquisition software PULSE and TIDA
  • Economical solution in comparison with the combination of several individual instruments
  • Complete control of each individual amplifier and optimized noise performance and grounding
  • Software controlled holding potential with a total range of
    +/- 1000 mV
  • Automation of experimental procedures
  • Automatic selftest and calibration
  • Automatic or manual adjustment of Cfast and Cslow.
  • Automatic or manual adjustment of the pipette offset in a range of +/- 200 mV
  • Automatic or manual Leak subtraction
  • Improved headstage design to reduce noise levels
  • Variable, high-quality hardware filters
  • Instant automatic neutralization of leakage currents, capacitance, and series resistance
  • Integrated ITC-16 AD/DA interface minimizes the total recording noise
  • Integration of hardware and software eliminates compatibility problems
  • True noise measurements from 100 Hz to 15 kHz
  • Suitable for single-channel and whole-cell measurements, loose patch experiments, capacitance measurements, recordings from plant cells and organelles, and studying reconstituted channels in artificial membranes
  • 100-130 V AC or 200-260 V AC switchable

  • See requirements
The EPC 9 Double/Triple patch clamp amplifier is no longer available. It was replaced by the improved EPC 10 Double/Triple amplifier.

The EPC 9 Double and EPC 9 Triple represent a new development in the field of patch clamp amplifiers. If you wish to perform double or triple patch experiments, the EPC 9 Double or EPC 9 Triple patch clamp amplifiers are the optimal solution for you. They multiply all properties which have made the EPC 9 the world's most efficient patch clamp amplifier by combining two or three amplifiers in a single instrument. The operation and handling are clearly defined and simple. The software stimulates the desired amplifier and enters the selected channels without tedious connecting of cables by the user. The amplifiers and the associated headstages are unambiguously identified. The operator can immediately assign the amplifiers to the patched cells. The software automatically recognizes the amplifier type (EPC 9, EPC 9 Double or EPC 9 Triple) ; hence the various instruments can be actuated, and data can be recorded, with the same software.

The EPC 9 Double and EPC 9 Triple provide an economical solution in comparison with the combination of several individual instruments; and offers complete control of each individual amplifier and optimized noise performance and grounding.